Menu

SELEVISCO 9000 Control Panels

Selevisco

The SELEVISCO 9000 control panel allows the display of data and command execution.

Each control panel manages a unit of measurement and can be applied within existing frameworks or supplied integrated into custom pulpits.

In manual mode the system displays the viscosity measured by a single sensor and allows the operator to add the solvent to correct the viscosity value.

In automatic mode the system compares the programmed viscosity value and the measured one. Based on the magnitude of this difference new solvent is added to correct the error. In case of malfunctioning or lack of solvent the system activates the proper visual and audible alarm to alert the operator.

The system has been designed to be auto-cleaning. The solvent enters directly in the measuring sensor both during the regulation step and when the cleaning function is activated at the end of the job. Adequate liquids should be used for the washing cycles according to the fluids’ mixture (normally the solvent is used as a thinner for the ink).
The supply should be connected directly to an inlet port located on the measuring head. The data displaying and the controls are incorporated into individual synoptics for each measuring unit that can be retrofitted into existing cubicles or integrated on personalized consoles.

TECHNICAL INFORMATION

  • Measuring range: 9…140 second (Ford-4)
  • Sensitivity: 0,1 sec
  • Max number of elements: 16 (Version Touch Screen) 1 (Version SV9000)
  • Alarm signal of viscosity controller: visual, audible and relay output